Abstract
BackgroundEfforts have been made to establish sensitive diagnostic tools for malaria screening in blood banks in order to detect malaria asymptomatic carriers. Microscopy, the malaria reference test in Brazil, is time consuming and its sensitivity depends on microscopist experience. Although molecular tools are available, some aspects need to be considered for large-scale screening: accuracy and robustness for detecting low parasitemia, affordability for application to large number of samples and flexibility to perform on individual or pooled samples.MethodologyIn this retrospective study, we evaluated four molecular assays for detection of malaria parasites in a set of 56 samples previously evaluated by expert microscopy. In addition, we evaluated the effect of pooling samples on the sensitivity and specificity of the molecular assays. A well-characterized cultured sample with 1 parasite/μL was included in all the tests evaluated. DNA was extracted with QIAamp DNA Blood Mini Kit and eluted in 50 μL to concentrate the DNA. Pools were assembled with 10 samples each. Molecular protocols targeting 18S rRNA, included one qPCR genus specific (Lima-genus), one duplex qPCR genus/Pf (PET-genus, PET-Pf) and one duplex qPCR specie-specific (Rougemont: Roug-Pf/Pv and Roug-Pm/Po). Additionally a nested PCR protocol specie-specific was used (Snou-Pf, Snou-Pv, Snou-Pm and Snou-Po).ResultsThe limit of detection was 3.5 p/μL and 0.35p/μl for the PET-genus and Lima-genus assays, respectively. Considering the positive (n = 13) and negative (n = 39) unpooled individual samples according to microscopy, the sensitivity of the two genus qPCR assays was 76.9% (Lima-genus) and 72.7% (PET-genus). The Lima-genus and PET-genus showed both sensitivity of 86.7% in the pooled samples. The genus protocols yielded similar results (Kappa value of 1.000) in both individual and pooled samples.ConclusionsEfforts should be made to improve performance of molecular tests to enable the detection of low-density parasitemia if these tests are to be utilized for blood transfusion screening.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.