Abstract

A numerical analysis of the lubricating film in spiral groove upstream pumping mechanical seals, accounting for the occurrence of cavitation, has been performed. Axial stiffness and leakage rate have been determined as functions of the operating conditions and design parameters. Results indicate that properly designed spiral groove upstream pumping seals will perform well in a double seal arrangement, with good stiffness characteristics and negative leakage of the buffer fluid. However, results also suggest that such seals will operate poorly as single seals, due to negative stiffness resulting from excessive cavitation. Presented at the 47th Annual Meeting In Philadelphia, Pennsylvania May 4–7, 1992

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.