Abstract
The phenomenon of PD(Partial Discharge) is accompanied by electromagnetic wave which can be detected by UHF(Ultra High Frequency) antenna. The signals obtaining from UHF antenna are very high rapid pulse and have wide band frequency responses. The distribution of PRPD(Phase Resolved Partial Discharge) which consisted of those pulse train can show distinct characteristics of PD sources. But it is not sufficient to discriminate among PD sources. This paper suggests that the stochastic parameters formed by preprocessing of STFT(Short Time Fourier Transform) are good tools for differentiate from PD sources. The stochastic parameters are CC(Cross Correlation) mean value, CC standard deviation, CC skewness, CC kurtosis.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of the Korean Institute of Electrical and Electronic Material Engineers
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.