This paper describes the application of catechin-modified titanium dioxide nanoparticles (TiO2 NPs) as matrices to analyze four steroid hormones by surface-assisted laser desorption/ionization mass spectrometry (SALDI-MS). The catechin-modified TiO2 NPs have high absorbance at 337nm and are effective SALDI matrices when using a nitrogen laser. Four test steroid hormones—cortisone, hydrocortisone, progesterone, and testosterone—were directly analyzed by SALDI-MS. The limits of detection at a signal-to-noise ratio of 3 for cortisone, hydrocortisone, progesterone, and testosterone were 1.62, 0.70, 0.66, and 0.23μM, respectively. This approach provides good quantitative linearity for the four analytes (R2>0.986) with good reproducibility (the shot-to-shot and batch-to-batch variations for the four analytes were less than 10% and 15%, respectively). We validated the practicality of this approach—considering its advantages in sensitivity, repeatability, rapidity, and simplicity—through the analysis of testosterone in a urine sample.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.