Abstract

The continuous slow feed of animal and vegetable oils is frequently found to be an economically attractive method for maintaining antibiotic fermentations at a highly productive rate. The sterilization of oil feeds can present a major problem in the production plant. In this article, we present data and methodology on the kinetics of the thermal sterilization of No. 2 lard oil and soybean oil. It was also determined that dry heat sterilization condition could occur if dry spores were added to dry oil. This condition could only be partially alleviated by the addition of water to the oil. The theory and design of a small tubular coil continuous sterilizer for sterilizing oils at the point of use is also presented. This type of sterilizer is economical and versatile and simplifies control and instrument requirements. It provides a realistic alternative to the use of sterile feed tanks and sterile headers.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.