Abstract

The aim of this study is to validate the sterility period of vials after multiple sampling under Grade A vertical laminar airflow hood. Vials filled aseptically with a sterile culture medium have been sampled with syringes three times a week over one month under Grade A vertical laminar airflow hood and in the mean-while, keeping the vials out of the laminar airflow hoods. No microbial growth has been observed. On the basis of these results, it has been decided to modify our standard operating procedures, to allow keeping the vials for two weeks in a box out of the laminar airflow hoods (ambient temperature Grade B) or any controlled environment (under refrigeration). This study validates the multiple use of vials of small to large volumes (5-100 mL), to simplify handling and to reduce the costs in centralized cytostatic reconstitution units in hospital pharmacies, with no microbial risk.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.