Abstract
IntroductionStereotactic radiosurgery (SRS) delivered to arrhythmogenic foci within the heart is a promising treatment modality. We dosimetrically evaluated the radiation dose to the organs at risk of four swine that were successfully treated with linear-accelerator-based SRS for atrioventricular (AV) node ablation.Materials and methodsSingle‐chamber pacemakers were implanted in four large white breed swine. Cardiac computed tomography simulation scans were performed to localize the AV node and organs at risk. SRS (35-40 Gy) was delivered to the AV node, and the pigs were followed up with pacemaker interrogations. One-sample t-tests were used to evaluate Dmax of great vessels, esophagus, and chest wall as compared to known normal tissue constraints as per RTOG 0631 and AAPM Task Group 101.ResultsAll pigs had disturbances of AV conduction with progressive transition into complete heart block. Macroscopic and microscopic evaluation showed fibrosis in the AV node but did not reveal any changes in non-nodal cardiac tissue or vessels. The mean Dmax±SD (p-value) of the chest wall (14.7±3.3 (0.02)), esophagus (10.7±1.1 (<0.01)) superior vena cava (3.3±4.1 (<0.01)), right pulmonary artery (16.1±6.4 (<0.01)), right pulmonary vein (15.7± 5 (<0.01)), left pulmonary artery (11.1±1.7 (<0.01)) and left pulmonary vein (14.1±2.6 (<0.01)), and the inferior vena cava (33.68±1.6 (0.026)) were significantly below the normal tissue constraint cutoffs. Mean±SD (p-value) of the ascending aorta (19.4±16.1 (0.12)) was not significantly different than normal tissue constraint cutoffs. One swine model treated at 40 Gy had small area of hotspot in the ascending aorta (40.65 (0.4 cc)).ConclusionWe have demonstrated in our swine models that SRS using 35-40 Gy can be done without exceeding known human normal tissue constraints to the chest wall, esophagus, and great vessels.
Highlights
Stereotactic radiosurgery (SRS) delivered to arrhythmogenic foci within the heart is a promising treatment modality
One swine model treated at 40 Gy had small area of hotspot in the ascending aorta (40.65 (0.4 cc))
The maximal dose to the esophagus, chest wall, inferior and superior vena cava, and all the pulmonary vasculature were significantly less than the established dose constraints, whereas there were no significant differences between the maximal dose to the ascending aorta when compared to the control values
Summary
Stereotactic radiosurgery (SRS) delivered to arrhythmogenic foci within the heart is a promising treatment modality. We dosimetrically evaluated the radiation dose to the organs at risk of four swine that were successfully treated with linear-accelerator-based SRS for atrioventricular (AV) node ablation
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.