Abstract

PurposeWe report our single-institution experience with stereotactic ablative radiotherapy (SABR) for adrenal metastasis and identify factors influencing outcomes, patterns of failure, and dosimetric thresholds for toxicity. Methods and materialsWe identified patients with adrenal metastases treated with SABR from 2009 to 2015. Toxicity was evaluated with Common Terminology Criteria for Adverse Events v4.0. Local failures were categorized as in-field, marginal, or out-of-field. New or progressive disease outside the treated adrenal gland was considered distant failure. Survival and time to local and distant failure were estimated by the Kaplan-Meier method. Prognostic factors were evaluated with a Cox proportional hazards model. Fisher’s exact tests were used to compare toxicity between dosimetric thresholds. ResultsForty-three patients with 49 adrenal metastases (84% from lung) were treated with SABR to a median prescribed dose of 60 Gy in 10 fractions. Median overall survival time was 19 months, and 1- and 2-year rates were 65% and 42%, respectively. Bilateral adrenal metastases were associated with worse overall survival (P = .01). Median progression-free survival (PFS) time was 6 months, with most progressions being distant failure (most often to brain or bone). PFS was better in patients with a solitary adrenal metastasis (P = .03). Median time to local failure was not reached; the 1-year freedom from local failure rate was 74%. Nine failures were in field and 1 was marginal; no local failures occurred in lesions treated with biologically equivalent doses of >100 Gy. No patient experienced grade 3-5 toxicity. Low-grade gastrointestinal toxicity was common, but grade 2 toxicity was avoided in patients with a maximum stomach-bowel point dose of ≤50 Gy (P = .03). Low-grade adrenal insufficiency was common with bilateral treatment. ConclusionSABR was well tolerated and resulted in good 1-year local control; PFS was promising for patients with solitary metastases. Low-grade toxicity was common, but can be minimized with strict dosimetric constraints.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.