Abstract

A method of analysis of hesperetin (+/−-3,5,7-trihydroxy-4′-methoxyflavanone) in biological fluids is necessary to study the kinetics of in vitro and in vivo metabolism and tissue distribution. A simple high-performance liquid chromatographic method was developed for simultaneous determination of hesperetin enantiomers in rat serum, and rat and human urine. Serum and urine (0.1 ml) were precipitated with cold acetonitrile after addition of the internal standard, 7-methoxycoumarin. Separation was achieved on a Chiralpak AD-RH column with UV detection at 298 nm. The calibration curve was linear ranging from 0.5 to 100 μg/ml for each enantiomer. The mean extraction efficiency was >98%. Precision of the assay was <5% (CV), and was within 5% at the limit of quantitation (0.5 μg/ml). Bias of the assay was lower than 5%, and was within 5% at the limit of quantitation. The assay was applied successfully to the urinary excretion of hesperetin in rats and humans.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.