Abstract

This paper aims to highlight the potential of stereolithographic models (SLM) as a tool in orbital surgical planning, and provides four examples of their role in facilitating successful surgery. Retrospective case series report. Case 1: SLM facilitated a successful orbital biopsy of a deep orbital mass by allowing several practice trucut biopsies. Case 2: Complex orbital fracture-repair was facilitated by using a SLM to demonstrate post-trauma and previous post-surgical-intervention bony anatomy. Case 3: Replication of accurate orbital anatomy in a case of severe socket contracture facilitated the selection of Branemark-implant placement sites to prevent inadvertent entry into the cranial cavity. Case 4: SLM prevented unnecessary surgical intervention. SLM are useful tools for pre-operative surgical planning, and have applications in selected complex orbital and oculoplastic cases.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call