Abstract
A stepwise multi-temperature thermogravimetric analysis (SMT-TGA) method is a rapid and time- and material-efficient measurement procedure for oxidation kinetics over a wide range of temperatures. It is suitable for alloy design and material selection procedures. It involves subjecting a sample to a series of steps at increasing temperatures, followed by steps at decreasing temperatures to identify possible effects on the evolution of oxide layer microstructures on oxidation kinetics. This method has been tested for a wide range of metallic alloys in the present work, allowing for the mapping of possible ranges of parabolic oxidation kinetics of industrial alloys between 600 and 1300°C. Two examples of effects of thermal history have also been described in this publication.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.