Abstract

It is not always possible to perform endoscopic retrograde cholangiopancreatography, and endoscopic ultrasound-guided biliary drainage (EUS-BD) has been performed as an alternative to percutaneous or surgical approaches [1,2]. The 2008 EUS Working Group summarized the indications, techniques, and complications of EUS-guided hepaticogastrostomy (EUS-HGS) [3]. The rate of complications reported for EUS-BD performed by experts was 0%–30%. Major complications included stent migration, bile leakage, peritonitis, and cholangitis [3,4]. A 58-year-old man had unresectable pancreatic cancer. He had undergone EUSguided choledochoduodenostomy and duodenal stent placement. Because obstructive jaundice was recurrent, EUSHGSwasperformedwith thepatient’s consent. A linear EUS scope was used. The intrahepatic bile duct (B3) was punctured with a 19-gauge needle (SonoTip Pro Control 19G; Medi-Globe GmbH, Rosenheim, Germany; Medico’s Hirata Inc., Osaka, Japan). After contrast mediumwas injected, a 0.025-inch guide wire (VisiGlide; Olympus Medical Systems, Tokyo, Japan) was introduced through the needle and placed into the common bile duct. The fistulawas dilated using a 9-Fr tapered biliary dilation catheter (Soehendra biliary dilation catheter; Cook Endoscopy; Bloomington, Indiana, USA). Finally, a fully covered metallic stent (8mm×8cm Wallflex; Microvasive Endoscopy, Boston Scientific, Natick, Massachusetts, USA) was placed. Inward stent migration occurred immediately (● Fig.1), which would be a fatal complication [4,5], and thereafter open surgical drainage was performed (● Fig.2). Fortunately, the man was able to resume oral intake after surgery; however, 44 days later, he died as a result of peritonitis carcinomatosa. Anatomically, the stomach is not directly attached to the liver, and during EUS-HGS there is no space between these organs when the echoendoscope is pressed against the stomach wall. Pulling back the echoendoscope for stent placement creates space between the liver and stomach wall. Given this complication, stents with lengths of 10 or 12cm should be used to avoid inward stent migration.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.