Abstract

We describe a patient after liver transplantation with a preexisting surgical splenorenal shunt close to the confluence of the splenic and superior mesenteric veins and a wide, short communication between the splenic and renal veins. To close the shunt, an inferior vena cava filter was inserted in the shunt and a vascular plug was placed in the splenic vein inside the filter. When this failed to stop the flow through the shunt, a covered stent was deployed at the superior mesenteric vein-portal vein junction.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.