Abstract

Within STEM mode the signal of both the inelastic and elastic scattered electrons contribute to the contrast of the image. This is an advantage compared to zero-loss filtered TEM imaging, where a significant amount of electrons are not contributing to the image formation, especially in thicker samples, due to multiple scattering events. In combination with an ultra sensitive HAADF-detector the scattering angle can be varied to obtain the best contrast, respectively signal to noise ratio, whatever gives more flexibility to optimize the signal compared to CCD camera acquisition. With CCD cameras these parameters are fixed. Especially, with radiation sensitive specimens it is advantageous to reduce a possible temperature increase by using a small area of illumination [1]. Thus, for a ten-fold increase in current density the temperature rise is much smaller for a focused probe than with flood-beam illumination. This is known as part of the “beam induced movement”. Minimizing this effect, directly increases the dose stability of the sample in STEM compared to TEM imaging. Furthermore, as a beneficial side effect, it improves the signal-to-noise ratio (SNR) in the images [2]. The sum of these effects clearly improves the image quality of negative stained viruses and sectioned biological material, which is shown in the comparison of STEM and TEM images of biological samples from the same area (Fig. 1, 2 and 3). It is striking to see the high contrast level of biological material in the STEM images. The lower frequencies are better preserved and though this will improve and facilitate, e.g. the alignment of individual particles for single particle analysis or for the alignment of tomographic tilt series. Finally, in modern microscopes, STEM in combination with low dose acquisition schemes is already implemented [3,4], easy to use and comparable to the convenient handling of a TEM in regular bright field mode. Thus, it increases the flexibility not only in tuning and adjusting of the microscope, but also in the possibility to choose the appropriate illumination mode and camera conditions enabling the user to get the best results from investigations of biological specimens.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.