Abstract

This paper presents a NDT by infrared thermography with a microwave excitation system. The advantages of such stimulation lie in the volumetric absorption of incoming waves which lead to a greater sounded depth. The device generating the microwaves was made of a commercial magnetron 800W at 2.45GHz associated with a pyramidal horn antenna. This method was applied to detect the steel reinforcements (deformed bar 12mm of diameter placing at every 10cm) in a concrete specimen (1m×1m×6.5cm) with a concrete cover of 3.8cm. The specimen was heated with an average power of 600W for 5min. An infrared camera was placed on the same side as the stimulated surface and thermograms were recorded at regular intervals. The whole assembly was placed in a protective enclosure against high frequency electromagnetic fields. The method based on a contrast algorithm was used to analyze the thermogram series. The result shows a higher temperature rise in front of the steel reinforcement areas. The effect of microwave caused an increase in moderate temperature does not lead to alteration of inspected concrete.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.