Abstract

Abstract The paper describes a study conducted on Steam Turbine control valve and actuation systems, which rule the machine final power production and rotational speed. A dynamic model developed in the Matlab/Simulink environment is proposed to support the analysis of the operational stability of the hydro-mechanical system as well as the failure modes that it may face during operation. The model was validated through specific field tests conducted on the actuation system at a cogeneration plant in Nuovo Pignone, Florence. The proposed work also underlines the requirements that new actuation technologies should fulfil in order to meet control valve system performance criteria.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.