Abstract
Steam oxidation test was carried out at 800 °C for 2000 h on nine plasma sprayed coatings on gamma-prime (γ’) strengthened Haynes® 282® Ni-based alloy. The lowest oxidation kinetics and extensive reduction in internal oxidation process was observed in the sample coated with nano CeO2 with no bond coat. This is due to the oxygen deficiency in CeOx that facilitates the inward movement of oxygen arising from the presence of Ce3+ oxidation state and ensures the quick formation of protective, impermeable and adherent layer of Cr2O3.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.