Abstract

A steam generator mock-up has been assembled for round-robin (RR) studies of the effectiveness of currently practiced inservice inspection technology for detection of current-day flaws. The mock-up will also be used to evaluate emerging inspection technologies. The 3.66 m (12 ft)-tall mock-up contains 400 tube openings, each consisting of nine test sections that can be used to simulate current-day field-induced flaws and artifacts. Included in the mock-up are simulations of tube support plate (TSP) intersections and the tube sheet (TS). Cracks are present at the TSP, TS, and in the free span sections of the mock-up. For initial evaluation of the RR results, various eddy current methods, as well as multivariate models for data analysis techniques are being used to estimate the depth and length of defects in the mock-up. To ensure that the RR is carried out with procedures as close as possible to those implemented in the field, input was obtained from industry experts on the protocol and procedures to be used for the exercise. One initial assembly of the mock-up with a limited number of flaws and artifact has been completed and tested. A second completed configuration with additional flaw and artifacts simulations will be used for the round robin.