Abstract

This paper presents the steady–state performance comparison between polyphase induction motor and polyphase TF motor operating in the asynchronous mode. It is shown graphically that a p-pole TF motor in operation is similar to an induction motor with 2p poles and hence its synchronous speed is limited to one-half (ω/2) of that of an induction motor. Additionally the pull-out torque of TF motor is inferior to that of an induction motor of the same dimensions, being less than ¼ of that of an equivalent induction motor on account of its higher leakage reqactance and in particular, the quadrature axis reactance. http://dx.doi.org/10.4314/njt.v34i2.24

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.