Abstract

Conventional pulse width modulation (PWM) controlled multi-port converters (MPCs) portray a narrow soft-switching range and higher RMS currents at light-load and non-unity gain conditions, leading to degraded end-to-end efficiency. Focusing on efficiency targeted limitations of conventional MPCs employed in electric vehicle (EV) charging applications, a comprehensive loss optimization study of a resonant Triple Active <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">C</i> <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sup> <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">L</i> <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sup> ( <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">TAC</i> <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sup> <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">L</i> <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sup> ) converter is presented in this paper. The multi-variable loss objective function is developed with constraints imposed to ensure zero voltage switching (ZVS) and synchronous rectification (SR) based soft-switching for all the corner conditions, by investigating the scope of optimal hybrid phase-duty-frequency modulation techniques. Based on the performance metrics obtained by employing hybrid modulation schemes, an algorithm is introduced to enable selection of least algorithmic complexity focused on digital implementation constraints that yields a steady-state operating zone matrix for different loading and port gain conditions. To benchmark the converter performance and the optimal modulation scheme selection criteria, an all-GaN based 2kW prototype is developed for a resonant frequency of 500kHz. Experimental validations for various loading conditions are presented for a wide-gain bidirectional operation (400V/500-600V/24-28V), that yield an efficiency improvement of ~1.2% as compared to conventional solutions, while portraying a peak converter efficiency of 97.42%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call