Abstract
The lumped-parameter thermal model is used to predict both the steady-state and transient solution to the temperatures within a 7.5-kW induction machine. The system of nonlinear ordinary differential equations and algebraic equations which describe the thermal behaviour of the machine in transient and steady states, respectively, were solved numerically using the Fourth-order Runge-Kutta method and the Gauss-Siedel method, respectively. The model performance is validated by experimental measurements on the test machine at rated load operation. The results show that there is a good agreement between the measured and predicted steady and transient states temperatures at rated load condition.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.