Abstract

This paper studies the application of high-frequency voltage excitation-based stator winding diagnostic methods to three-phase ac machines operated from power converters that create the necessary high-frequency excitation as part of their normal operation. This paper focuses on two specific operating modes: 1) machines operated from inverters in the overmodulation region and 2) machines operated from soft-starters during startup. In both cases, high-frequency (in the range of the hundred hertz) voltage components at well-defined frequencies are created. The negative-sequence currents induced from these high-frequency voltages are shown to contain accurate information on the level of asymmetry (fault) in the machine. This information is significantly richer than exists in other modes of operation, i.e., inverters working in the linear modulation region or soft-starters in the steady state, and provides interesting opportunities to complement other diagnostic methods.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.