Abstract

From the measured thermal dissipation rate in turbulent Rayleigh–Bénard convection in a cylindrical cell, we construct a locally averaged thermal dissipation rate χ fτ by averaging over a time interval τ. We study how the statistical moments ⟨(χ fτ) p ⟩ depend on τ at various locations along the vertical axis of the convection cell. We find that ⟨(χ fτ) p ⟩ exhibits good scaling in τ, of about a decade long, with scaling exponents μ(p) for p = 1–6. For Rayleigh number (Ra) around 8×109, the scaling range is 1.4–21 s at the cell center and 4–21 s at the bottom plate. The dissipative and turnover times are about 0.8 s and 35 s respectively, while the timescale corresponding to the local Bolgiano scale is estimated to be about 31 s at the cell center and 3.5 s at the bottom plate. On the basis of several assumptions, we derive theoretical predictions for μ(p) at the different locations. The measured values of μ(p) are presented and shown to be in good agreement with our theoretical predictions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.