Abstract
The internal lubricant content (ILC) of inhalation grade HPMC capsules is a key factor to ensure good powder release when the patient inhales a medicine from a dry powder inhaler (DPI). Powder release from capsules has been shown to be influenced by the ILC. The characteristics used to measure this are the emitted dose, fine particle fraction and mass median aerodynamic diameter. In addition the ILC level is critical for capsule shell manufacture because it is an essential part of the process that cannot work without it. An experiment has been applied to the manufacture of inhalation capsules with the required ILC. A full factorial model was used to identify the controlling factors and from this a linear model has been proposed to improve control of the process.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.