Abstract

An equation is found for the steady-state probability density function of the modulo-2π-reduced phase error of a secondorder phase-locked loop (PLL) with a proportional-proportional-plus-integral control type filter. The equation involves a certain conditional expectation which has been evaluated in an approximate way following the same approach used by previous authors in the case of sole Gaussian noise. With this approximation the equation becomes of the same type as that pertinent to a first-order system and therefore it can be solved with a method described by Ohlson in [3]. Theoretical results obtained in this way are complemented by experimental observations gathered by simulating the PPL on a digital computer.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.