Abstract

This article presents the research process and statistical analysis of the selection of an appropriate type of surfactant to be added to natural ester oil MIDEL eN 1204. The tested parameter was the breakdown voltage. The following surfactants were tested: Triton X, ROKwino l80, and oleic acid. With the obtained results, we can conclude that the surfactants with the best properties, compared to the basic oil sample, have oleic acid, and also that high levels of breakdown voltage characterize a sample of Triton X with a concentration of 2%. Statistical analysis was performed using the MATLAB program.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.