Abstract

The static response of capacitive pressure sensors with a thin rectangular or square diaphragm is studied, assuming small deflections. Lagrange's equation is solved from the virtual displacement theorem and an approximated polynomial solution. It is shown that response can be expressed under a normalized form dependent only on the value of the diaphragm dimension ratio. For a given silicon surface, square sensors exhibit the highest sensitivity whereas rectangular sensors have a more linear behaviour. Finally, the proposed formulation equally allows easy and rapid determination of the four geometric parameters defining this type of sensor Etude de la reponse en regime statique du capteur, dans l'hypothese des deformations faibles

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.