Abstract

An experimental study on a static pressure measurement errors in wall taps was conducted using a high Reynolds number actual flow facility (Hi-Reff). The bulk Reynolds number ReD examined was up to 1.3 × 107 and tap Reynolds number Ret was up to 8.5 × 104. The behavior of the static pressure measurement error at high Reynolds numbers was clarified experimentally. The static pressure measurement error normalized by wall shear stress increases with Reynolds number and reaches an asymptotic value. Its maximum value is 7.1 at Ret = 8470. The asymptotic value increases with the size of the tap diameter up to 6 mm and then becomes constant for tap diameters exceeding 6 mm. The universal curve reported in previous studies is observed for only a limited range of tap Reynolds numbers of below 700 and of tap diameters below 4 mm.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.