Abstract

ABSTRACT This paper describes compressive static load tests of concrete driven piles confined by Carbon Fibre Reinforced Polymer (CFRP). The tested piles include one concrete pipe pile and one concrete rectangular pile which are all partially confined by CFRP, and other two piles with the same dimensions without CFRP application. Tests program was performed to obtain the behaviours of these composite piles. Four Static Loading Tests (SLTs) were conducted and the results shown that those two types of composite pile demonstrate less vertical displacement with the same loading of traditional concrete piles. Furthermore, the traditional methods of Load-settlement (Q-s) curves, Settlement-lg (Load) (s-lgQ) curves and Settlement-lg (Time) curves are analysed. Due to un-plunging condition, the interpretation methods of Davisson’s, DeBeers, Double-Tangent as well as Chin’s methods are demonstrated for the ultimate bearing capacity of these four piles. It is concluded that the CFRP confinement increased the ultimate bearing capacity and this composite material can be perfectly applied in geotechnical condition.