Abstract

AbstractFIBC use is increasing rapidly owing principally to improved handling efficiency and product quality improvement. However, selection of the proper FIBC has many aspects, of which safety is paramount. Numerous accidents have occurred when emptying flammable powders from FIBCs, both with and without flammable vapors additionally present. Owing to the mode of operation and speed of emptying, not only is there a high probability of static generation but also a high probability of one or more operators being in the flash fire zone should ignition occur. Apart from the flash fire produced by a dust cloud and/or flammable vapors displaced from a receiving vessel, a flame may in some cases propagate into the FIBC, which might then explode. This paper discusses the FIBC selection problem, a series of case histories, and available literature. Since no FIBC loading incidents are known, the paper will focus on emptying. In particular it should be appeciated that the potential for operator grounding error and sudden nemesis can be very high.