Abstract

A no-load induction motor under static eccentricity is modeled using time stepping finite element (TSFE) method; current, torque, and speed signals of the motor are obtained by finite element method (FEM) and used for static eccentricity fault diagnosis and analysis. The frequency spectrum analysis of the stator current around fundamental frequency component is used to predict the static eccentricity. Noise, unbalanced magnetic pull (UMP) and arc occur during the starting of the faulty motor, therefore, performance of the motor over the period of starting up to the steady-state is investigated. It is shown that the rate of obtained signals from the constant permeability based analysis is very larger than that of the real case. It is indicated that in order to obtain accurate results the saturation must be taken into account in the analysis of the motor. Simulation results for a 3 hp, three-phase, 230 V, 36 stator slots induction motor with 28 rotor slots are given in this paper. Experimental results for the motor confirm the simulation results very well.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.