Abstract

Push-out tests were conducted to investigate the different behavior between single-stud and multi-stud connectors. The results show that the single-stud and multi-stud connectors have the similar stiffness, and the spacing of studs has little influence in the stiffness of multi-stud connectors. The ultimate strength of single-stud connector is about 10% larger than multi-stud connectors. When the load reaches its peak, the relative slip of single-stud connector is about 19% larger than that of multi-stud connectors. The multi-stud effect on static behavior of shear connector is negligible. Based on the push-out test results, a new expression of stud load-slip relationship was proposed. Compared to existing relationships, the new expression has a better match with the experimental values. The static behavior was studied and compared to design equations. The results show that the estimation based on Eurocode-4 agrees well with the multi-stud test results and the estimations based on AASHTO LRFD and Chinese code agree well with the single-stud test results.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.