Abstract

A new design of a radially retractable roof structure based on the concept of the suspen-dome is proposed in this paper. The radially foldable bar structure is strengthened by the lower cable-strut system to obtain a higher structural stiffness. Then the comparison of the static behavior between the retractable suspen-domes and their corresponding foldable bar shell with quadrangular mesh is discussed. Moreover, the effects of different structural and geometric parameters, such as the rise-to-span ratio, the cross-section area of beams, cables and struts, and the pre-stress level of the lower cable-strut system, on the nodal displacements and member forces are investigated systematically. The results show that higher structural stiffness is anticipated with the introduction of cable-strut systems into the hybrid structure. When the rise-to-span ratio is equal to 0.2, the maximal nodal displacement of the suspen-dome reaches the minimal value. The increase of the cross-section area of steel beams contributes an enormous amount to the structural stiffness. Increasing cable and strut sections has little impact on the mechanical behavior of suspen-domes. Moreover, the prestress level of cable-strut systems has a slight influence on the nodal displacements and member forces. Parametric analysis can be regarded as an essential basis for the optimization of the design of a retractable suspen-dome structure.

Highlights

  • The structural behaviors of single-layer domes are continually investigated [1,2,3,4], and stability remains amongst the challenges faced for longer spans [5]

  • The nodal displacements and axial forces in the steel beams of the retractable suspen-domes are compared with the single-layer foldable bar structure without any supporting cable-strut system

  • It can be found that the axial stresses in the steel bars are slightly lower in the suspen-dome, and the differences are more notable near the mid-span again in the case of Load 2

Read more

Summary

Introduction

The structural behaviors of single-layer domes are continually investigated [1,2,3,4], and stability remains amongst the challenges faced for longer spans [5]. Among different types of systems interest of many practitioners, designers, andtheresearchers These basic[21,22], units consis those using angulated scissor-like elements These basic units consist of a angle as their rods rotate while maintaining the end pivots on parallel lines [24,25]. The current investigation was developed advance the foldabl merit ofTherefore, increased stability from suspen-dome systems;. 2, which is followed by a comparison of the static behavior between the retractable suspen-dome requirements

A parametric study of thesuspen-dom static
Finite Element Model
Finite
Discussion on the Initial Prestress Level in the Cable-Strut System
10. Displacement
Influence of the Rise-to-Span
Influence of the Cross-Section Area of Steel Beams
Influence of Cable of
Influence of Cross-Section Area of Struts
Influence
Conclusions
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call