Abstract

A simultaneous visualization and measurement study has been carried out to investigate the start-up, heat transfer and flow characteristics of three silicon-based micro pulsating heat pipes (MPHPs) with the trapezoidal cross-section having hydraulic diameters of 251μm (#1), 352μm (#2) and 394μm (#3), respectively. Experiments were performed under different working fluids, filling ratios, inclination angles (bottom heating mode) and heating power inputs. It is found that (1) the silicon-based MPHPs could start up within 200s when charged with R113 or FC-72, but they failed to start up at all inclination angle when charged with water or ethanol having lower (dP/dT)sat, higher viscosity, higher latent heat and higher surface tension at the same temperature. During the start-up period, no obvious nucleation was observed. After the start-up period, MPHPs entered the operation period. The silicon-based MPHP could operate normally even at a Bond number of 0.26 and a hydraulic diameter of 251μm, both smaller than the corresponding values in literatures; (2) the thermal performance of MPHPs depends greatly on the type of working fluid, filling ratio and inclination angle. At the lower power input, MPHPs charged with R113 showed better thermal performance than that charged with FC-72, however, the latter exceeded the former at the higher power input. For the same working fluid, there existed an optimal filling ratio corresponding to the best thermal performance of MPHPs, which was about 52%, 55% and 47% for MPHPs #1, #2 and #3 at the vertical orientation (90°), respectively. When the MPHPs turned from the vertical to the horizontal orientation, the thermal performance tended to be decreased, indicating that the gravity effect cannot be ignored in these silicon-based MPHPs. In MPHP #3 at the inclination angle from 70° to 90°, there appeared a special thermal resistance curve with two local maximum points, which is absent in the traditional PHPs; (3) in the operation period of larger MPHP #3, nucleation boiling, bulk circulation and injection flow were all observed, while these flow patterns were absent in the smaller MPHPs #1 and #2. Intense liquid film evaporation, instead of bubbles’ generation and expansion which usually activated the oscillation flow in macro-PHPs, drove the two-phase flow in the smaller MPHPs #1 and #2.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.