Abstract
In this work, an experimental-numerical evaluation of the standing contact fatigue testing of a nitrided AISI 316L steel was developed. The nitride layers were formed at the surface of an AISI 316L steel by a salt bath nitriding process at a temperature of 580 °C for 1, 3 and 5 h of exposure time, obtaining three different layer thicknesses. In order to know the mechanical response and the different mechanisms of damage associated with the standing contact fatigue test, Hertzian tests were performed on a MTS machine by cyclic loading of a sphere on a flat surface formed by the layer/substrate system. The standing contact fatigue test was developed through two main stages. First, the critical loads for each treatment condition were determined by monotonic tests, where the appearance of circular cracks was considered as the failure criterion. Subsequently, cyclic subcritical loads were applied at a frequency of 5 Hz. A numerical model based on the finite element method was developed to evaluate the stress field generated in the system by cyclic contact loads. The results indicate that the thinnest thickness of nitride layer exhibits better resistance to standing contact fatigue.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.