Abstract

This study presents a new design for the jaws used in the uniaxial tensile testing of PA6 electrospun membranes. The aims of the new design are both to accelerate the clamping process and additionally reduce the paper waste created by paper frames. In order to validate the efficiency of the new design, the newly developed jaws were compared both with currently used paper frames and the direct positioning of samples in metal jaws. It was demonstrated that the new jaws reduced the clamping time by half. Moreover, the maximal stress and strain values were observed to be higher than those of the metal jaws and the paper frames. Finally, it was determined that the new design enables the testing of wetted samples, which is problematic using paper frames.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.