Abstract

This study aims to assess and predict lifespan of dental prostheses using newly developed Korean Association of Prosthodontics (KAP) criteria through a large-scale, multi-institutional survey. Survey was conducted including 16 institutions. Cox proportional hazards model and principal component analysis (PCA) were used to find out relevant factors and predict life expectancy. 1,703 fixed and 815 removable prostheses data were collected and evaluated. Statistically significant factors in fixed prosthesis failure were plaque index and material type, with a median survival of 10 to 18 years and 14 to 20 years each. In removable prosthesis, factors were national health insurance coverage, antagonist type, and prosthesis type (complete or partial denture), with median survival of 10 to 13 years, 11 to 14 years, and 10 to 15 years each. For still-usable prostheses, PCA analysis predicted an additional 3 years in fixed and 4.8 years in removable prosthesis. Life expectancy of a prosthesis differed significantly by factors mostly controllable either by dentist or a patient. Overall life expectancy was shown to be longer than previous research.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.