Abstract

PurposeThe evaluation of syncope is often disorganized and ineffective. The objective of this study was to examine whether implementation of a standardized emergency department (ED) protocol improves the quality of syncope evaluation.Materials and MethodsThis study was a prospective, non-randomized study conducted at a 1900-bed, tertiary teaching hospital in South Korea. We compared two specific periods, including a 12-month observation period (control group, January-December 2009) and a 10-month intervention period after the implementation of standardized approaches, comprising risk stratification, hospital order sets and establishment of a syncope observational unit (intervention group, March-December 2010). Primary end points were hospital admission rates and medical costs related to syncope evaluation.ResultsA total of 244 patients were enrolled in this study (116 patients in the control group and 128 patients in the intervention group). The admission rate decreased by 8.3% in the intervention group (adjusted odds ratio 0.31, 95% confidence interval 0.13-0.70, p=0.005). There was a cost reduction of about 30% during the intervention period [369000 Korean won (KRW), interquartile range (IQR) 240000-602000 KRW], compared with the control period (542000 KRW, IQR 316000-1185000 KRW). The length of stay in the ED was also reduced in the intervention group (median: 4.6 hours vs. 3.4 hours).ConclusionStandardized approaches to syncope evaluation reduced hospital admissions, medical costs and length of stay in the overcrowded emergency department of a tertiary teaching hospital in South Korea.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call