Abstract
As ultrasonography provides objective parameters and values, it is a reliable method of examining the structure and dimensions of the masseter muscle. Although the method is well known, there is no standardization in clinical examination and data analysis yet. The study aimed to measure masseter muscle thickness in designated areas to establish the most repeatable and clinically applicable method of ultrasound examination, and to assess differences in measurements in designated areas for clinical purposes by devising the size-independent parameter. The size-independent parameter may potentially be more clinically applicable than distance records, which are affected by the size of the subject. An ultrasound examination of 124 masseter muscles was performed. Axial examination in 3 horizontal regions (lower, middle and upper) and coronal examination in 2 vertical regions (proximal and distal) was carried out. Masseter muscle thickness was measured in every designated area when relaxed (muscle at rest (RMT)) and with clenched teeth (contracted muscle (CMT)). A morphological independent functional index of thickness difference (FITD) was calculated. The study revealed very high statistical differences between RMT and CMT (p < 0.0001) in all designated areas but with location variations. Masseter muscle thickness significantly differed depending on the examined area and transducer projection. The ultrasound study showed that masseter muscle thickness significantly differs depending on the examined area. The authors emphasize the necessity to examine the masseter muscle in specified areas with both coronal and axial projections to achieve objective and repeatable examination. Notable clinical value is assigned to FITD, which is independent from the morphological dimensions of the muscle.
Highlights
As ultrasonography provides objective parameters and values, it is a reliable method of examining the structure and dimensions of the masseter muscle
Masseter muscle thickness significantly differed depending on the examined area and transducer projection
The ultrasound study showed that masseter muscle thickness significantly differs depending on the examined area
Summary
As ultrasonography provides objective parameters and values, it is a reliable method of examining the structure and dimensions of the masseter muscle. Ultrasound examination is considered to be useful for functional analysis of the masticatory organ[1,2] and diagnosis of alterations in the muscles of mastication.[3] It provides objective parameters and values; it is an effective, accurate, low-cost, and reliable method of examining the structure and dimensions of the masseter muscle.[4,5] The most often investigated parameter, because of its clinical value and ease of measurement, is masseter muscle thickness. Significant negative correlations with mandibular plane angle and gonial angle were observed.[9,10] It was proved that masseter muscle thickness influences the growth of the jaws.[11]
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Advances in clinical and experimental medicine : official organ Wroclaw Medical University
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.