Abstract

We present the trial-and-error process of standardizing robot-assisted radical nephroureterectomy (RANU) at a high-volume center in Japan. Our urology team performed 53 RANU cases using the Da Vinci Xi system, undergoing five major evolutionary stages. We performed RANU via transperitoneal approach in all cases and lymph-node dissection in selected cases. During the evolution, we adopted a lithotomy position and significantly modified port placement to facilitate lower ureter management. However, we ultimately arrived at a method that minimizes port and patient repositioning during lower ureter processing. By strategically placing ProGrasp™ forceps in the most caudal port, we effectively retracted the bladder and grasped the opened bladder wall during lower ureter manipulation. This approach also allowed us to perform pelvic, para-aortic, and renal portal lymph-node dissection without major changes in patient positioning or port placement. Nevertheless, we acknowledge that some variations in positioning and techniques may be necessary depending on specific case requirements.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.