Abstract

In this work we present a stand-alone, portable system for high resolution real-time THz imaging. The total weight of the apparatus is less than 15 kg and its physical dimension is of ~(65 cm)3. A quantum cascade laser emitting at 3.4 THz laser based on a third-order distributed feedback cavity is used as source. It operates in continuous-wave at 50 K with more than 1 mW output power and less than 300 mW of power consumption. High resolution real-time THz imaging is reported: resolution of 2.5 times the wavelength is demonstrated.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.