Abstract

AbstractThis work presents the results of an experimental investigation on the behavior of 21 solid clay brick columns internally strengthened by stainless steel grids placed in the horizontal joints of mortar. This reinforcing technique can be applied as a constructive technique for new construction or as a retrofitting technique for existing structures (old structures to be reconstructed by original constructive method and internal reinforcement). Monotonic compressive loading tests were carried out under concentric and eccentric load. The effects of different numbers of steel grids and eccentricity of the external load were examined. Also, a detailed characterization of the constituent materials was made experimentally. The compression tests show the effectiveness of the proposed strengthening technique, which proves to be able to produce the increases in strength and energy required to collapse brick columns under both concentric and eccentric loads. To provide an analysis method for practical applica...

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.