Abstract

Objective. To test the effect of two measurement techniques for repeated measures of spine height using stadiometry following five experimental activity conditions. Design. Six subjects were repeatedly measured while they stepped in and out of the stadiometer for each pair of measures and again on another day when they remained in place in the stadiometer for all 10 measures. Results. There was much greater variability in height measures with the “in–out” method while the “in place” method demonstrated a steady shrinkage over the 3–3.5 min required to obtain the repeated measures. Relevance Contrary to popular practice, leaving a subject in the stadiometer during repeated measures includes the shrinkage that occurs over the 3–3.5 min of measurement when standing and reduces random variation due to posture change.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.