Abstract

The integrity of metallic interconnectors (MICs) in a solid oxide cell stack is crucial because contact resistances or limitations in gas supply may occur. In this contribution, a Crofer 22 APU® interconnector with a (Mn, Co, Fe)3O4 spinel oxide (MCO) coating and a lanthanum-strontium-manganese-cobalt oxide (LSMC) contact layer at the air side was investigated. The electrochemical behavior was characterized by means of IV-characteristics, impedance spectroscopy and DRT analysis. In particular, the contact losses at the air side were measured with targeted potential probes. With respect to the contact layer mounted in a dried state, the application of a stack-like clamping pressure of 1MPa showed a significant decrease of the contact resistance. In order to extend an existing zero-dimensional performance model for an electrolyte-supported cell with a Ni/GDC fuel electrode and LSCF air electrode, a method was established to parameterize contact losses at the air electrode. The observed activation energy of the contact losses showed to be independent of the clamping pressure. Additionally, the dependency of the cell´s intrinsic ohmic losses towards the steam partial pressure at the Ni/GDC fuel electrode was quantified and included to the model. Simulation studies were validated with experimental data for technical operating conditions.