Abstract

A quantitative assay for 3-hydroxyisovaleric acid in amniotic fluid was developed using D6-3-hydroxyisovaleric acid as an internal standard. 3-Hydroxyisovaleric acid was isolated by liquid partition chromatography and the amount determined by selected ion monitoring, ammonia chemical ionization gas chromatography-mass spectrometry of the trimethylsilyl derivatives. The concentration of 3-hydroxyisovaleric acid in ten normal amniotic fluid was 4.52 +/- 1.73 mumol/l. The level was elevated eight-fold in the amniotic fluid from a pregnancy resulting in the birth of a child with biotin-responsive multiple carboxylase deficiency. The stable isotope dilution assay of 3-hydroxyisovaleric acid in amniotic fluid is a rapid, sensitive and accurate method for the prenatal diagnosis of this disorder, and may be of value in the prenatal diagnosis of other inherited disorders of leucine catabolism.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.