Abstract

CO(2) samples were collected from air at three sites in Hungary for comparison of polluted and background areas. In order to reduce the uncertainties caused by the varying amount of N(2)O, a gas chromatography (GC)-based vacuum separation was applied. The reliability of the procedure was demonstrated by careful standardization and comparison with global network data. The stable isotope data show complex diurnal and seasonal variations that can be explained by fractionations during photosynthesis and respiration. The isotopic characteristics of pollution-derived (anthropogenic) and biogenic CO(2) appear to be indistinguishable at the study sites. However, the sites at unpolluted areas reveal a seasonal variation in the carbon isotope composition of biogenic CO(2) that may be related to changes in soil biogenic activities. The atmospheric background CO(2) shows constant delta(13)C in the region. Finally, the study demonstrates the need for careful standardization of sampling in order to make the data obtained from different sampling systems comparable.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.