Abstract

The One-Cycle Controlled Boost Power Factor Correction converter has one voltage control loop, which may exhibit instability when the load is light. The instability results in a low Power Factor. To ensure that the Power Factor is high, a time delay circuit was adopted in this paper to control the instability of the converter. The architecture of the time delay circuit is described, and its transfer function is derived. The double averaging method was applied to the converter to determine the parameters in the control method. Experimental results verified the time delay control method in the converter. The power factor increased from 0.82 to 0.99 after activating the delay control circuit.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.