Abstract
Stabilization of pelvic osteotomy with a 2.7 mm dynamic compression plate (DCP) for the treatment of hip dysplasia, was performed in 42 operations in 27 dogs. Screw loosening was observed in 11 osteotomies (26%), plate bending in six cases (14%) and plate breakage in two cases (4%). An in vitro experiment using the pelvic bones of young mixed breed dogs showed no significant difference in the holding power of AO/ASIF 2.7 mm cortical, 3.5 mm cortical and 3.5 mm fully threaded cancellous screws in the body of the ilium. The 2.7 mm DCP has an advantage over the 3.5 DCP in stabilizing pelvic osteotomy because it allows more screws to be used per unit length of plate, which possibly results in a more stable fixation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Veterinary and Comparative Orthopaedics and Traumatology
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.