Abstract

The superconducting magnet system of the Wendelstein 7-X (W7-X) stellarator experiment consists of 50 non-planar and 20 planar coils which are supported by the central support structure and inter-coil structure elements. This highly loaded support system is prone to mechanical disturbances like stick-slip effects. On the other hand, the coils are built up from cable-in-conduit-conductors (CICC) whose strands are highly compressed by Lorentz forces during operation. Residual elastic energy release within a cable can be triggered by shock waves and corresponding frictional heat generation may occur. The released energy might come into the order of the conductor stability limit and possibly cause a quench. An experiment was performed to simulate the impact of such mechanical disturbances on W7-X coils with stability margins corresponding to different operation conditions. A non-planar coil installed within the magnet test facility was energized and then hit by a pendulum via a stainless steel transfer rod. The test has shown that mechanical disturbances expected in W7-X are not able to induce a quench in any of the foreseen W7-X operation scenarios.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.