An experimental study of stability between two types of short-cavity laser configurations is carried out. The short-cavity lasers are comprised of one or two pairs of wavelength-matched FBGs, encompassing a short length of highly-doped Er-fiber, to create effectively single- or dual-wavelength fiber lasers. The laser performance in terms of the laser output power and laser stability in relation to the gain medium length was investigated experimentally, analyzed and reported in this letter.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.